Resources › Tools › MCB Rating Selector
Chandigarh Tricity

MCB Rating Selector

Select a circuit type to see the typical MCB rating and curve used for Indian home wiring.

Quick answer

What MCB for a geyser?

A domestic geyser runs well on a dedicated 16 A C-curve MCB with 4 sq mm copper wire. The C-curve handles the initial heating surge without nuisance tripping.

How this works

An MCB protects the wire, so its rating must match the circuit's cable and load. B-curve MCBs trip faster and suit lights and sockets; C-curve MCBs tolerate the brief inrush of motors and are used for ACs, geysers and kitchen appliances.

Rating vs curve — two different things

An MCB has two numbers that matter. The rating (amps) must match the cable so the breaker trips before the wire overheats. The curve (B, C or D) sets how fast it trips on a surge. A B-curve trips quickly and suits resistive loads like lights and sockets; a C-curve tolerates the brief inrush of motors and is used for ACs, geysers and kitchen appliances.

Match the MCB to the cable, not the appliance

The golden rule: size the cable for the load first, then fit the largest MCB that cable can safely carry. Fitting a bigger breaker to stop nuisance tripping leaves the wire unprotected — if a circuit keeps tripping, the real cause is an overload, the wrong curve, or a genuine fault, not a breaker that is too small.

CircuitMCBCurveCable
Lighting6 AB1.5 sq mm
Power sockets16 AB2.5 sq mm
Geyser16 AC4 sq mm
Air conditioner (1.5T)20 AC4 sq mm
Kitchen (heavy)20 AC4 sq mm
Main isolator (2-3 BHK)40-63 AC10-16 sq mm

Frequently asked questions

What MCB for a geyser?

A domestic geyser runs well on a dedicated 16 A C-curve MCB with 4 sq mm copper wire. The C-curve handles the initial heating surge without nuisance tripping.

What is the difference between B and C curve?

A B-curve trips at 3-5 times its rating and suits lights and sockets. A C-curve trips at 5-10 times and suits motor loads like ACs, pumps and geysers that surge at start-up.

Why does my MCB keep tripping?

Usually an overloaded circuit, the wrong curve for the load, or a genuine fault. Fitting a larger MCB hides the problem and removes the cable's protection — find the cause instead.